CCTSST-FR0.3 n×1×1.4

Application

The cables are used as railway cables and can be installed directly into the ground or in ducts.

Standard

  • RENFE E.T. 03.365.051.6

Cable Construction

CCPSSP-FR-0.3-n×1×1.4
  • Conductors: Soft annealed solid copper, 1.4 mm nominal diameter.
  • Insulation: PE insulation.
  • Stranding: Cores are helically stranded in concentric layers.
  • Core Wrapping: Two or more layers of plastic tape(s) with overlapping.
  • Screen: Copper tapes with overlap (protection against interference).
  • Inner Sheath: FRNC-PE sheath, coloured green.
  • Armour: Two layers of steel tape (0.8mm thick).
  • Outer Sheath: FRNC-PE sheath, coloured green.

Electrical Characteristics at 20℃

Nominal Conductor Diameter mm 1.4
Maximum Conductor Resistance Ω/km 11.7
Minimum Insulation Resistance @500 V DC MΩ.km 35000
Resistance Unbalance % 2
Test Voltage @50Hz 1min
Core to Core Veff 2100
Core to Screen Veff 2500
Reduction Factor @100V/km 50Hz 0.3

Mechanical and Thermal Properties

  • Minimum Bending Radius: 10×OD
  • Temperature Range: -40℃ to +60℃ (during operation); -10℃ +60℃ (during installation)

Dimensions and Weight

Cable Code Number of
Cores
Nominal Sheath Thickness
mm
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
Inner Outer
1.4mm Conductor, 2.6mm Insulated Wire
RS/CCTSST-FR0.3-2Y(K)HBH-4C1.4 4 1.5 1.6 18.0 705
RS/CCTSST-FR0.3-2Y(K)HBH-19C1.4 19 1.6 1.8 26.1 1362
RS/CCTSST-FR0.3-2Y(K)HBH-27C1.4 27 1.6 1.8 29.2 1648
RS/CCTSST-FR0.3-2Y(K)HBH-48C1.4 48 1.7 1.8 36.7 2348